Otokar Administration Building

Simple-box energy modelling and optimisation were completed for Otokar Administration Building. Orientation, envelope, glazing and lighting options were compared to inform early design decisions. Location: Sakarya, Türkiye.

View the project analysis

Project analysis

Across 518 simulations, energy-focused, investment-balanced and larger-glazed-area options became comparable on a consistent model basis.

Interactive project analysisOpen in a new tab

The analysis loads as you reach this section.

Terms used in the analyses
sDA
Spatial Daylight Autonomy — the share of floor area that reaches 300 lux from daylight alone for at least half of the occupied hours (IES LM-83).
ENERGY STAR
ENERGY STAR score — a 1–100 operational performance score from the US Environmental Protection Agency, comparing a building’s energy performance with that of similar buildings.
Tier 1
Tier 1 — the top category of the LEED renewable energy credit, which includes renewable energy generated on site.